Paper
6 May 1999 Image distortion in conventional and confocal microscopy
Simone Loehner, Ian T. Young, Stephanie L. Ellenberger, Michiel de Bakker
Author Affiliations +
Proceedings Volume 3605, Three-Dimensional and Multidimensional Microscopy: Image Acquisition and Processing VI; (1999) https://doi.org/10.1117/12.347586
Event: BiOS '99 International Biomedical Optics Symposium, 1999, San Jose, CA, United States
Abstract
A well-known distortion of objects in three-dimensional microscopy manifests itself as an elongation in the axial direction. Authors such as Visser and Hell have seemingly contradicted one another on the cause as well as the magnitude of the effect. We have examined these theories and performed simulations and experimental measurements to better understand the nature of the effect. We simulate point spread functions (based on the work of Gibson) taking into account the various refractive indices involved as well as the magnification, the numerical aperture, the working distance of the objective, the depth of the object under the coverslip, and the object's size. We measure the axial and lateral dimensions of digitized images of microspheres that have been 'acquired' using a simulated point spread function that changes as the depth of the object changes. These simulations are done for conventional (optical sectioning) microscopy as well as for confocal microscopy. Further, we have performed experimental measurements on real microspheres on a conventional microscope to relate theory, simulation, and practice. Our measurements and simulations show that (1) the object's size, (2) its depth under the coverslip, (3) the refractive index mismatch between the immersion fluid (nimmersion) and embedding material for the object (nembedded), and (4) the NA of the lens play a pivotal role in the effect.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Simone Loehner, Ian T. Young, Stephanie L. Ellenberger, and Michiel de Bakker "Image distortion in conventional and confocal microscopy", Proc. SPIE 3605, Three-Dimensional and Multidimensional Microscopy: Image Acquisition and Processing VI, (6 May 1999); https://doi.org/10.1117/12.347586
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Confocal microscopy

Microscopes

Point spread functions

Objectives

Refractive index

Optical transfer functions

Computer simulations

Back to Top