7 June 1999 Output power enhancement by the injection of dissociated iodine in supersonic chemical oxygen-iodine laser
Author Affiliations +
Abstract
Iodine molecule was dissociated prior to injection in supersonic Chemical Oxygen-Iodine Laser (COIL). In some cases, output power enhancement was observed. However, the output power was decreased at the optimum titration (iodine/oxygen ratio). A quasi-two dimensional simulation was employed to analyze the effect ofiodine pre-dissociation. It was revealed that the high iodine atom concentration at the plenum is responsible for the power reduction. The method to improve the output power by pre-dissociation is discussed.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Masamori Endo, Masataka Kawakami, Shuzaburo Takeda, Fumio Wani, and Tomoo Fujioka "Output power enhancement by the injection of dissociated iodine in supersonic chemical oxygen-iodine laser", Proc. SPIE 3612, Gas and Chemical Lasers and Intense Beam Applications II, (7 June 1999); https://doi.org/10.1117/12.350637