24 May 1999 Effect of denoising on the consistency of manually defined borders
Author Affiliations +
Abstract
This paper presents experimental results and analysis for a study of the effect of de-noising on the consistency and reliability of manually-defined borders of echocardiograms. De-Noising and image enhancement have been performed on a test data set of 60 sequences from an echocardiographic database exhibiting diverse image quality. Both endocardial and epicardial borders of end diastolic and end systolic frames were manually identified for original and enhanced images based on image perception and wall motion information. Statistical analysis was performed on the identified borders. The experimental results show that de-noising and image enhancement help to improve the consistency of the manually- defined borders for the data set.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Xuli Zong, Xuli Zong, Edward A. Geiser, Edward A. Geiser, Donald A. Conetta, Donald A. Conetta, } "Effect of denoising on the consistency of manually defined borders", Proc. SPIE 3663, Medical Imaging 1999: Image Perception and Performance, (24 May 1999); doi: 10.1117/12.349648; https://doi.org/10.1117/12.349648