You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
14 June 1999Factors that determine the optimum reduction factor for wafer steppers
The optimum reduction factor for stepper lenses is determined by trade-offs among several competing constraints and practical limitations. Lens reduction factor were chosen initially on the basis of several factors, including maximum lens element size, usable reticle field, stepper throughput and reticle glass size. These considerations led to the choice of 5x for the reduction factor initially and 4x for the most recent generation of step-and-scan systems. A large reduction factor is beneficial because it reduces the negative impacts of reticle linewidth variations, reticle registration errors, and reticle defects. This is particularly important for optical lithography processes that operate near the diffraction limit, where the mask error factor can be large. For this reason, as well travel down the roadmap, the 4x reduction factor for critical stepper lenses needs to be reconsidered. Before a decision is made, all consequences of a large reduction factor must be taken in to account. For fixed field sizes, reduction factors have been limited to 4x in order to achieve compatibility between 26 mm X 33 mm field sizes and 6 inch reticles, and the assumption of large die size. The reduction factor of 4x can be reconsidered if prior predictions of large die size are not realized of capability for making 230 mm reticles becomes available. The economics of 230 mm reticles changes favorably when the reduction factor is increased. Large reduction factors have relatively neutral effects on lens cost, but will make fast scanning more difficult. A proposal for a possible new optimum reduction is given from the analysis of these critical factors.
The alert did not successfully save. Please try again later.
Harry J. Levinson, Paul W. Ackmann, Moshe E. Preil, William T. Rericha, "Factors that determine the optimum reduction factor for wafer steppers," Proc. SPIE 3677, Metrology, Inspection, and Process Control for Microlithography XIII, (14 June 1999); https://doi.org/10.1117/12.350834