26 July 1999 160 x 128 uncooled FPA performance review
Author Affiliations +
Abstract
This paper presents background and measured performance data on a novel, low cost, high performance readout integrated circuit (ROIC) for microbolometer uncooled detector applications. The array is designed to offer better than 80mK NEdT performance using f/1.8 optics. The design incorporates advanced on-ROIC signal processing electronics that allow bolometer element non-uniformity control over a wide range of ROIC substrate temperatures. The small format array is ideally suited for high volume low-cost production applications.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jeffery L. Heath, Jeffery L. Heath, Glenn T. Kincaid, Glenn T. Kincaid, James T. Woolaway, James T. Woolaway, William J. Parrish, William J. Parrish, Dieter Lohrmann, Dieter Lohrmann, Gwendolyn W. Newsome, Gwendolyn W. Newsome, Adrian Inosecu, Adrian Inosecu, John Monson, John Monson, Christopher J. Rau, Christopher J. Rau, Philip E. Howard, Philip E. Howard, Chuan C. Li, Chuan C. Li, } "160 x 128 uncooled FPA performance review", Proc. SPIE 3698, Infrared Technology and Applications XXV, (26 July 1999); doi: 10.1117/12.354527; https://doi.org/10.1117/12.354527