Paper
8 December 1999 Performance stability of the sapphire fiber and cladding under high temperature
Yonghang Shen, Limin Tong, Shuying Chen
Author Affiliations +
Proceedings Volume 3852, Harsh Environment Sensors II; (1999) https://doi.org/10.1117/12.372835
Event: Photonics East '99, 1999, Boston, MA, United States
Abstract
This paper concentrates on the performance stability of sapphire fiber thermometer probe and the development of an alumina fiber cladding durable under high temperature and of high transparency. Analysis was made on the performance stability of sapphire fiber probe under high temperature when using different kinds of protective tube. It is found that direct contacting of the fiber with protective tubes is the most important factor that result in performance deterioration and the dirtying of evaporating substance is another important factor. Then it is applicable to design a suitable protective tube to assure the performance stability.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yonghang Shen, Limin Tong, and Shuying Chen "Performance stability of the sapphire fiber and cladding under high temperature", Proc. SPIE 3852, Harsh Environment Sensors II, (8 December 1999); https://doi.org/10.1117/12.372835