Paper
30 November 1999 Range-resolved frequency-agile CO2 lidar measurements of smokestack vapor effluents
Author Affiliations +
Abstract
Range-resolved lidar measurements of chemical vapor output from a smokestack were conducted using a moderate-power (100 millijoules per pulse) frequency-agile CO2 differential absorption lidar (DIAL) system. A 70-foot non-industrial smokestack, erected for the purpose of studying effluent emissions, was used in the experiment. These measurements were conducted for the purpose of obtaining real data to support development of advanced chemical and biological (CB) range- resolved vapor detection algorithms. Plume transmission measurements were made using natural atmospheric backscatter from points at the mouth of the stack and several positions downwind. Controlled releases of triethyl-phosphate (TEP), dimethyl-methylphosphonate (DMMP), and sulfur-hexaflouride (SF6) were performed. Test methodology and experimental results are presented. Effective application of ground-based lidar to the monitoring of smokestack effluents, without the use of fixed targets, is discussed.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Francis M. D'Amico, Richard G. Vanderbeek, and Russell E. Warren "Range-resolved frequency-agile CO2 lidar measurements of smokestack vapor effluents", Proc. SPIE 3855, Air Monitoring and Detection of Chemical and Biological Agents II, (30 November 1999); https://doi.org/10.1117/12.371272
Lens.org Logo
CITATIONS
Cited by 7 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
LIDAR

Sensors

Carbon dioxide

Algorithm development

Liquids

Mouth

Atmospheric particles

Back to Top