Paper
25 October 2000 Beam sampler for third harmonic diagnostics in ICF system
Jinyu Wang, Yingbai Yan, Lin Pang, Qiaofeng Tan, Guofan Jin
Author Affiliations +
Abstract
The design of the Shenguang system calls for a beam sampler to provide 3rd harmonic laser energy for diagnostics in the highly constrained area of the target chamber, The beam sampler should diffract 0.01%-0.5% of the 3rd harmonic light into a calorimeter at a small angle to estimate its corresponding energy. In order to achieve low efficiency beam sampling with the least energy lost, two kinds of surface-relief grating have been designed with different method. One is the rectangular phase grating with its step height and width optimized. Another one is the sinusoidal phase grating. For each kind of beam sampler, the permissible fabrication errors have been analyzed. The characteristics of them have been compared in detail.
© (2000) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jinyu Wang, Yingbai Yan, Lin Pang, Qiaofeng Tan, and Guofan Jin "Beam sampler for third harmonic diagnostics in ICF system", Proc. SPIE 4095, Laser Beam Shaping, (25 October 2000); https://doi.org/10.1117/12.405262