25 January 2001 Investigation of split-electrode configurations for high-power diffusion-cooled annular CO2 lasers
Author Affiliations +
Proceedings Volume 4184, XIII International Symposium on Gas Flow and Chemical Lasers and High-Power Laser Conference; (2001) https://doi.org/10.1117/12.414065
Event: XIII International Symposium on Gas Flow and Chemical Lasers and High-Power Laser Conference, 2000, Florence, Italy
Abstract
For a kW annular diffusion-cooled laser, we tested the possibility of using the electrodes directly as waveguide wall. We considered dielectric and metallic spacers. Electric field distribution calculations and preliminary experimental results are presented.
© (2001) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Antonio Lapucci, Marco Ciofini, R. M. Celli, Silvano Mascalchi, L. Roselli, G. L. Emili, "Investigation of split-electrode configurations for high-power diffusion-cooled annular CO2 lasers", Proc. SPIE 4184, XIII International Symposium on Gas Flow and Chemical Lasers and High-Power Laser Conference, (25 January 2001); doi: 10.1117/12.414065; https://doi.org/10.1117/12.414065