9 November 2000 Evaluation of sapphire-ruby single crystal fiber for thermometric use up to 1500°C
Author Affiliations +
Proceedings Volume 4185, Fourteenth International Conference on Optical Fiber Sensors; 418505 (2000) https://doi.org/10.1117/12.2302148
Event: Fourteenth International Conference on Optical Fiber Sensors, 2000, Venice, Italy
Abstract
Results of an evaluation of a single crystalline sapphire fiber with a Cr3- doped (ruby) tip for thermometric use up to 1500°C are reported. The study shows that the single crystal probe is able to operate continuously at temperatures up to 1400°C. and can reliably cover a wide temperature measurement range from -50°C to 1400°C.
© (2000) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yonghang Shen, Yonghang Shen, } "Evaluation of sapphire-ruby single crystal fiber for thermometric use up to 1500°C", Proc. SPIE 4185, Fourteenth International Conference on Optical Fiber Sensors, 418505 (9 November 2000); doi: 10.1117/12.2302148; https://doi.org/10.1117/12.2302148