Paper
1 June 2001 Microwave array applicator for radiometry-controlled superficial hyperthermia
Paul R. Stauffer, Svein Jacobsen, Daniel Neuman
Author Affiliations +
Abstract
Hyperthermia therapy has been shown clinically effective for a variety of skin diseases but current heating equipment is inadequate for most patients. This effort describes the design and performance of a flexible microstrip array applicator intended for heating large regions of tissue over contoured anatomy while at the same time monitoring temperature of the underlying tissue by non-invasive radiometric sensing of blackbody radiation from the heated volume. For this dual purpose applicator, an array of broadband Archimedean spiral receive antennas is integrated into an array of Dual Concentric Conductor heating apertures. Applicator heating uniformity is assessed with electric field scans in homogenous muscle phantoms and with measured temperature distributions in clinical treatments of chestwall recurrence of breast carcinoma. The data demonstrate precisely controlled heating out to the perimeter of large (40 x 13 cm2) multiaperture conformal array applicators. Capabilities of the radiometry system are assessed by correlation of brightness temperatures measured in phantom loads of known temperature distribution as seen through an intervening 5 mm thick water bolus at constant 40°C. The radiometer demonstrates excellent sensitivity and an accuracy of +0.1-0.45°C for temperature measurements up to 5 cm deep in phantom when using a one dimensional weighting function analysis and up to 6 independent 500 MHz bandwidths within the 1-4 GHz range. The data clearly indicate that both heating and radiometric thermometry are possible using the same thin and flexible printed circuit board microstrip array applicator. Once development is complete, this dual mode conformal array applicator with multiplexed radiometric display system should provide significantly improved uniformity and ease of heating large area superficial tissue disease.
© (2001) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Paul R. Stauffer, Svein Jacobsen, and Daniel Neuman "Microwave array applicator for radiometry-controlled superficial hyperthermia", Proc. SPIE 4247, Thermal Treatment of Tissue: Energy Delivery and Assessment, (1 June 2001); https://doi.org/10.1117/12.427866
Lens.org Logo
CITATIONS
Cited by 14 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Antennas

Temperature metrology

Radiometry

Synthetic aperture radar

Tissues

Microwave radiation