9 July 2001 Reduction of protection from laser eyewear with ultrashort exposure
Author Affiliations +
Abstract
We have measured the optical density of various laser eye protection samples as a function of increasing irradiance. We show that the protective quality of some eyewear degrades as irradiance increases. In previous studies this problem has been demonstrated in samples irradiated by nanosecond pulses, but the current study shows that the modern laser eye protection seems to be robust except for the irradiance possible with ultrashort laser pulse exposure. We discuss the most likely saturation mechanisms in this pulse duration regime and discuss relevance to laser safety.
© (2001) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
David J. Stolarski, Jacob Stolarski, Gary D. Noojin, Benjamin A. Rockwell, and Robert J. Thomas "Reduction of protection from laser eyewear with ultrashort exposure", Proc. SPIE 4257, Laser-Tissue Interaction XII: Photochemical, Photothermal, and Photomechanical, (9 July 2001); https://doi.org/10.1117/12.434695