You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
9 December 1983The Testing Of Meniscus Refractive Corrector Elements
One method of correcting the aberrations of a mirror system is to add refractive corrector elements to the design. These elements provide the degrees of freedom required to achieve a corrected solution. An example of this approach is the Maksutov catadioptric system. This system consists of a primary mirror, in front of which is located a highly meniscus negative element. The meniscus element provides the compensation of the spherical aberration introduced by the spherical mirror. Many systems have been designed and constructed with more than one mirror and with multi-element corrector arrangements. The Maksutov system, consisting of a single spherical mirror and a single refractive element, is an example of the simplest form of correction using meniscus elements. In the fabrication of a well-corrected catadioptric system, which is required to perform near its theoretical limit, it is necessary to test the corrector elements to a high degree of accuracy. This paper describes the design of a special purpose tester for a particular refractive meniscus corrector element, the Strong Shell of the Perkin-Elmer Micralign Model 500 Projection Mask Alignment System. The Model 500 is a catadioptric system used by the semiconductor industry for optical microlithography on silicon wafers. A key factor in the optical design of the special purpose tester was to arrive at a solution that would allow all elements within their constructional tolerances for radius, thickness, and wedge to be evaluated with little further adjustment to the tester. This characteristic greatly accelerates testing and improves test data repeatability. This was accomplished by the selection of the testing conjugate point, a key factor in the overall design of the tester. A brief description of the Model 500 optical design, including the function of the strong shells is provided. Also provided is a description of the tester as well as the methods for alignment and certification.
Irwin Friedman
"The Testing Of Meniscus Refractive Corrector Elements", Proc. SPIE 0433, Contemporary Methods of Optical Manufacturing and Testing, (9 December 1983); https://doi.org/10.1117/12.936806
The alert did not successfully save. Please try again later.
Irwin Friedman, "The Testing Of Meniscus Refractive Corrector Elements," Proc. SPIE 0433, Contemporary Methods of Optical Manufacturing and Testing, (9 December 1983); https://doi.org/10.1117/12.936806