22 October 2001 Portable I2-stabilized Nd:YVO4/KTP laser for secondary wavelength standards at 532 nm
Author Affiliations +
Proceedings Volume 4401, Recent Developments in Traceable Dimensional Measurements; (2001) https://doi.org/10.1117/12.445629
Event: Lasers in Metrology and Art Conservation, 2001, Munich, Germany
Abstract
We have designed and tested a portable Nd:YVO4/KTP/I2 laser system at 532 nm. Using a conventional third- harmonic-locking servo system, Allan variances less than 1 10-12 have been obtained for time interval s greater than 100 s.
© (2001) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jean-Marie Chartier, Jean-Marie Chartier, Leonid F. Vitushkin, Leonid F. Vitushkin, Mikhail Khaleyev, Mikhail Khaleyev, Georgii E. Novikov, Georgii E. Novikov, Oleg A. Orlov, Oleg A. Orlov, Sergey Terekhov, Sergey Terekhov, Vladimir I. Ustugov, Vladimir I. Ustugov, } "Portable I2-stabilized Nd:YVO4/KTP laser for secondary wavelength standards at 532 nm", Proc. SPIE 4401, Recent Developments in Traceable Dimensional Measurements, (22 October 2001); doi: 10.1117/12.445629; https://doi.org/10.1117/12.445629