Abstract
This paper proposes a calibration system consisting of three components: a quasi-linear intrinsic calibrator, a linear extrinsic calibrator and a nonlinear L-M optimizer. The focal length is evaluated form vanishing points. Then the rotation matrix and the translation vector are estimated linearly. At last a Levenberg-Marquardt optimization is performed to refine the extrinsic parameters by minimizing the reprojection error. The parameterization of the rotation matrix is discussed in detail, and two parameterization methods, Euler-Angle and Axis-Angle are compared. Experimental results prove that the system can calibrate the cameras precisely.
© (2001) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Qing Wu, Qing Wu, Guang-you Xu, Guang-you Xu, Lei Wang, Lei Wang, } "Three-stage system for camera calibration", Proc. SPIE 4553, Visualization and Optimization Techniques, (25 September 2001); doi: 10.1117/12.441552; https://doi.org/10.1117/12.441552