3 May 2002 Digital system based on a bichromatic x-ray source and a single-photon counting device: a single-exposure dual-energy mammography approach
Maria Giuseppina Bisogni, S. Fabbri, Mauro Gambaccini, Michele Marziani, Marzia Novelli, Mariagrazia Quattrocchi, Valeria Rosso, Paolo Russo, A. Sarnelli, Arnaldo Stefanini, Sergio Zucca
Author Affiliations +
Abstract
In this work we exploit the advantages of using a bi-chromatic X-rays source coupled with a single photon counting pixel detector to perform a feasibility study for dual energy mammography. This technique allows enhancing the contrast between different breast tissues by composing two images acquired at two different energies. The high and low energy images have been acquired by a single X-ray shot. The bi-chromatic beam has been produced per diffraction of polychromatic photons by a monochromator crystal. The imaging system is based on a single photon counting silicon pixel detector. The data read-out is performed by a VLSI Integrated Circuit bump-bonded to the sensor. The energy threshold of each electronics channel can be individually trimmed. We set the threshold of one pixel below 16 keV while the threshold of the neighboring pixel between 16 and 32 keV. With a single exposure the information from both energies is recorded. After separation between low and high threshold pixels, we obtained two independent images. We acquired radiographs of phantoms made of three different materials. Appling a dual energy algorithm, we obtained synthesized images where any of the three materials is removed from the radiograph, enhancing the contrast between the two remaining.
© (2002) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Maria Giuseppina Bisogni, S. Fabbri, Mauro Gambaccini, Michele Marziani, Marzia Novelli, Mariagrazia Quattrocchi, Valeria Rosso, Paolo Russo, A. Sarnelli, Arnaldo Stefanini, and Sergio Zucca "Digital system based on a bichromatic x-ray source and a single-photon counting device: a single-exposure dual-energy mammography approach", Proc. SPIE 4682, Medical Imaging 2002: Physics of Medical Imaging, (3 May 2002); https://doi.org/10.1117/12.465607
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Signal to noise ratio

Aluminum

Sensors

Calibration

Dual energy imaging

Digital mammography

Crystals

RELATED CONTENT

The AGIPD System for the European XFEL
Proceedings of SPIE (May 03 2013)
New Developments In Digital X-Ray Detection
Proceedings of SPIE (November 04 1981)
Calibrating the wings of the Chandra PSF
Proceedings of SPIE (February 03 2004)
Aspects of x-ray microtomography equipment design
Proceedings of SPIE (October 26 2004)
A very compact polarizer for an x-ray polarimeter calibration
Proceedings of SPIE (September 13 2007)

Back to Top