24 April 2002 Multislice spiral CT simulator for dynamic cardiopulmonary studies
Author Affiliations +
Abstract
We've developed a Multi-slice Spiral CT Simulator modeling the acquisition process of a real tomograph over a 4-dimensional phantom (4D MCAT) of the human thorax. The simulator allows us to visually characterize artifacts due to insufficient temporal sampling and a priori evaluate the quality of the images obtained in cardio-pulmonary studies (both with single-/multi-slice and ECG gated acquisition processes). The simulating environment allows both for conventional and spiral scanning modes and includes a model of noise in the acquisition process. In case of spiral scanning, reconstruction facilities include longitudinal interpolation methods (360LI and 180LI both for single and multi-slice). Then, the reconstruction of the section is performed through FBP. The reconstructed images/volumes are affected by distortion due to insufficient temporal sampling of the moving object. The developed simulating environment allows us to investigate the nature of the distortion characterizing it qualitatively and quantitatively (using, for example, Herman's measures). Much of our work is focused on the determination of adequate temporal sampling and sinogram regularization techniques. At the moment, the simulator model is limited to the case of multi-slice tomograph, being planned as a next step of development the extension to cone beam or area detectors.
© (2002) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Silvia De Francesco and Augusto Marques Ferreira da Silva "Multislice spiral CT simulator for dynamic cardiopulmonary studies", Proc. SPIE 4683, Medical Imaging 2002: Physiology and Function from Multidimensional Images, (24 April 2002); https://doi.org/10.1117/12.463596
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Stereolithography

Distortion

Lithium

Process modeling

Electrocardiography

Environmental sensing

Image processing

RELATED CONTENT

Shape-based interpolation of nD gray scenes
Proceedings of SPIE (April 15 1996)
A high capacity reversible watermarking scheme
Proceedings of SPIE (January 19 2009)
Phase-based image quality assessment
Proceedings of SPIE (April 06 2005)
Efficient transformation algorithm for 3-D images
Proceedings of SPIE (June 01 1991)

Back to Top