9 September 2002 Testing micro-optical bonds per Telcordia qualifications
Author Affiliations +
Abstract
A method has been developed for testing the stability of micro-optical bonds. A white light interferometer is used to measure the movement of micro-optical components after each of a series of Telcordia tests. The micro-optical components were subjected to accelerated high temperature soak, thermal cycling, thermal shock and 500 G mechanical shock. This method allows us to have a high level of confidence that our optical bonds will be sufficiently stable throughout the service life of our tunable laser product. Using accelerated testing techniques and not performing environmental tests that have been shown to induce minimal or no movement, we have found that 30 days is the time required to adequately evaluate the stability of a micro-optical bond design.
© (2002) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Patrick A. Bournes, Patrick A. Bournes, Vijay F. Thadani, Vijay F. Thadani, } "Testing micro-optical bonds per Telcordia qualifications", Proc. SPIE 4771, Optomechanical Design and Engineering 2002, (9 September 2002); doi: 10.1117/12.482177; https://doi.org/10.1117/12.482177
PROCEEDINGS
8 PAGES


SHARE
RELATED CONTENT

A High Accuracy Surface Contour Measuring Machine
Proceedings of SPIE (April 03 1979)
Tunable optical fiber grating using a memory alloy actuator
Proceedings of SPIE (December 03 2005)
Replication Of Refracting Optics
Proceedings of SPIE (October 13 1977)
Broadband tunable Fabry-Perot cavity for infrared range
Proceedings of SPIE (April 21 1996)

Back to Top