5 February 2003 Radiation-induced changes in the solid state detector performance for the Mercury atmospheric and surface composition spectrometer (MASCS)
Jennifer A. Turner-Valle, Virginia Ann Drake, William E. McClintock, Greg Holsclaw, Richard H. Mauer
Author Affiliations +
Abstract
Two Hamamatsu photodiode array detectors of the type that will be flown in the MASCS instrument on the MErcury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) mission to Mercury were subjected to proton radiation to verify survival in the mission radiation environment and quantify expected levels of radiation-induced degradation of the dark field response during the mission. These same detector types were also evaluated for susceptibility to latch-up due to ionizing radiation.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jennifer A. Turner-Valle, Virginia Ann Drake, William E. McClintock, Greg Holsclaw, and Richard H. Mauer "Radiation-induced changes in the solid state detector performance for the Mercury atmospheric and surface composition spectrometer (MASCS)", Proc. SPIE 4796, Low-Light-Level and Real-Time Imaging Systems, Components, and Applications, (5 February 2003); https://doi.org/10.1117/12.450881