22 May 2002 Realization and dissemination of linear acceleration unit at UME
Author Affiliations +
Proceedings Volume 4827, Fifth International Conference on Vibration Measurements by Laser Techniques: Advances and Applications; (2002) https://doi.org/10.1117/12.468172
Event: Fifth International Conference on Vibration Measurements by Laser Techniques, 2002, Ancona, Italy
Abstract
At Turkish National Metrology Institute (UME), linear acceleration unit has been realized based on laser interferometry with different signal processing techniques. Absolute calibrations of reference accelerometers are performed by using fringe-counting and minimum point method in the frequency range from 20 to 10000 Hz. Dissemination of the linear acceleration unit to the secondary levels is carried out through a comparison calibration of vibration pick-ups by "backto- back" method. Traceability chain for calibrations of the vibration calibrations and measurements performed at UME has been described in this paper.
© (2002) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Enver Sadikoglu, Eyup Bilgic, Baki Karaboece, "Realization and dissemination of linear acceleration unit at UME", Proc. SPIE 4827, Fifth International Conference on Vibration Measurements by Laser Techniques: Advances and Applications, (22 May 2002); doi: 10.1117/12.468172; https://doi.org/10.1117/12.468172