11 March 2003 In orbit calibrations of XMM-Newton telescopes
Author Affiliations +
Abstract
We describe in-orbit measurements of the mirror vignetting in the XMM-Newton Observatory, using observations of SNR G21.5-09 with the EPIC imaging cameras. The instrument features that complicate these measurements are briefly described. We show the spatial and energy dependences of measured vignetting, outlining assumptions made in deriving the eventual agreement between theory and measurement. Alternate methods to confirm these are described. We briefly describe an analysis of the stray-light rejection of the telescope.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
David H. Lumb, David H. Lumb, A. Finoguenov, A. Finoguenov, Richard Saxton, Richard Saxton, Bernd Aschenbach, Bernd Aschenbach, Philippe Gondoin, Philippe Gondoin, Marcus Kirsch, Marcus Kirsch, I. M. Stewart, I. M. Stewart, } "In orbit calibrations of XMM-Newton telescopes", Proc. SPIE 4851, X-Ray and Gamma-Ray Telescopes and Instruments for Astronomy, (11 March 2003); doi: 10.1117/12.461334; https://doi.org/10.1117/12.461334
PROCEEDINGS
9 PAGES


SHARE
RELATED CONTENT

Ground based x ray calibration of the Astro H soft...
Proceedings of SPIE (July 24 2014)
The Swift X-Ray Telescope
Proceedings of SPIE (February 03 2004)
Swift x-ray telescope (XRT)
Proceedings of SPIE (March 11 2003)
In-orbit calibration of the XMM-Newton telescopes
Proceedings of SPIE (December 13 2000)

Back to Top