21 March 2003 Application of clock distributor in SLR system
Author Affiliations +
Abstract
This paper presents the test results of a clock distributor, which was applied to Changchun and Beijing Satellite Laser Ranging (SLR) system. It gives out the ground target calibration results and ranging satellite results. After applying the clock distributor, the precision of calibrating ground targets and ranging satellites has several mm improvements. It also shows the comparison results of standard frequency source provided only by HP58503A GPS receiver and by HP58503A GPS receiver through the clock distributor.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
You Zhao, You Zhao, Peter Sperber, Peter Sperber, Tanqiang Wang, Tanqiang Wang, Cunbo Fan, Cunbo Fan, Chengzhi Liu, Chengzhi Liu, Xinwei Han, Xinwei Han, } "Application of clock distributor in SLR system", Proc. SPIE 4893, Lidar Remote Sensing for Industry and Environment Monitoring III, (21 March 2003); doi: 10.1117/12.466670; https://doi.org/10.1117/12.466670