30 August 2002 Pixel matrix detector for digital radiography applications
Author Affiliations +
Abstract
In this paper the performance of a GaAs detector based on a pixel matrix architecture is experimentally evaluated. Several spectral distribution have been obtained for a single GaAs pixel and compared with that of a reference Si sample in order to determine the Charge Collection Efficiency and the Energetic Resolution. The obtained results indicate the detector ability to interact with low-energy X-ray to generate good quality images for high-contrast details
© (2002) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Maria Rizzi, Maria Rizzi, Beniamino Castagnolo, Beniamino Castagnolo, } "Pixel matrix detector for digital radiography applications", Proc. SPIE 4925, Electronic Imaging and Multimedia Technology III, (30 August 2002); doi: 10.1117/12.481583; https://doi.org/10.1117/12.481583