20 June 2003 Ocular hazards of Q-switched near-infrared lasers
Author Affiliations +
Abstract
The threshold for laser-induced retinal damage in the rhesus eye was determined for wavelengths between 900 nm and 1300 nm. The laser source was a tunable Optical Parametric Oscillator (OPO) pumped by the 3rd harmonic of a Nd:YAG laser. The laser pulse duration was 3.5 ns. The wavelength dependence of the injury threshold is consistent with the prediction of a model based on the transmission of the preretinal ocular media, absorption in the retinal pigment epithelium, and variation of irradiance diameter resulting from chromatic aberration of the eye optics for wavelengths shorter than 1150 nm but was less consistent for longer wavelengths. The threshold for 24-hour observation was slightly lower than the threshold for 1-hour observation. These data form a basis for reexamination of the currently defined MPEs for wavelengths longer than 1100 nm.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
David J. Lund, David J. Lund, Peter R. Edsall, Peter R. Edsall, Bruce E. Stuck, Bruce E. Stuck, } "Ocular hazards of Q-switched near-infrared lasers", Proc. SPIE 4953, Laser and Noncoherent Light Ocular Effects: Epidemiology, Prevention, and Treatment III, (20 June 2003); doi: 10.1117/12.488646; https://doi.org/10.1117/12.488646
PROCEEDINGS
6 PAGES


SHARE
RELATED CONTENT

Ocular hazards of Q-switched blue wavelength lasers
Proceedings of SPIE (May 16 2001)
Spectral dependence of retinal thermal injury
Proceedings of SPIE (March 02 2000)
Limiting mechanism for NIR laser retinal damage
Proceedings of SPIE (February 12 2009)
Wavelength dependence of laser-induced retinal injury
Proceedings of SPIE (April 17 2005)
Compact DIAL sensor: SHREWD
Proceedings of SPIE (August 21 2001)
Action spectrum for retinal thermal injury
Proceedings of SPIE (June 17 1999)

Back to Top