5 June 2003 Full-field images of mammographic phantoms obtained with a single photon counting system
Salvator Roberto Amendolia, Maria Giuseppina Bisogni, Pasquale Delogu, Maria Evelina Fantacci, Stefania Linsalata, Marzia Novelli, Mariagrazia Quattrocchi, Valeria Rosso, Arnaldo Stefanini, Sergio Zucca
Author Affiliations +
Abstract
As the use of digital radiographic equipment in the morphological imaging field is becoming largely diffuse, the research of new and more performing devices from public institutions and industrial companies is in constant progress. Many of these devices are based on solid-state detectors as X-ray sensors. Semiconductor pixel detectors, originally developed in the high energy physics environment, have been then proposed as digital detector for medical imaging applications. In this paper a digital single photon counting device, based on silicon and GaAs pixel detectors, is presented. The detector is a thin slab of semiconductor crystal equipped with an array of 64 by 64 square contacts, 170-μm side. The data read-out is performed by a VLSI integrated circuit named Photon Counting Chip (PCC), developed within the MEDIPIX collaboration. Each chip cell geometrically matches the sensor pixel. It contains a charge preamplifier, a threshold comparator and a 15 bits pseudo-random counter and it is coupled to the detector by means of bump-bonding. Most important advantages of such a system, with respect to a traditional X-rays film/screen device, are the wider linear dynamic range (3x104) and the higher performance in terms of MTF and DQE. Electronics read-out performance as well as imaging capabilities of the digital device will be presented. Images of mammographic phantoms acquired with a standard mammographic tube will be compared with radiographs obtained with traditional film/screen systems.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Salvator Roberto Amendolia, Maria Giuseppina Bisogni, Pasquale Delogu, Maria Evelina Fantacci, Stefania Linsalata, Marzia Novelli, Mariagrazia Quattrocchi, Valeria Rosso, Arnaldo Stefanini, and Sergio Zucca "Full-field images of mammographic phantoms obtained with a single photon counting system", Proc. SPIE 5030, Medical Imaging 2003: Physics of Medical Imaging, (5 June 2003); https://doi.org/10.1117/12.480144
Lens.org Logo
CITATIONS
Cited by 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Signal to noise ratio

Modulation transfer functions

Imaging systems

Silicon

Calibration

Mammography

Back to Top