Paper
23 May 2003 Encoded multiple simultaneous aperture acquisition for improved signal-to-noise ratio in ultrasound imaging
Hany M. G. Hussein, Abou-Bakr M. Youssef, Yasser M. Kadah
Author Affiliations +
Abstract
Here, we propose a new technique that allows the improvement of SNR without lowering the frame rate. The basic version of the proposed technique works by exciting multiple non-overlapping apertures at the same time. Assuming N apertures are to be acquired simultaneously, N acquisitions from such arrangement are made with different aperture coding in each acquisition. In particular, the excitation to each aperture is multiplied by a different predetermined factor for each acquisition. By properly selecting these factors, the problem of estimating the different lines become equivalent to solving a well-conditioned linear system of size N. Also, we show that such factors can be chosen to make the system matrix orthogonal, thus enabling simple solution to be obtained. We describe the implementation of such procedure and demonstrate that it is possible to achieve in practice even for systems in which the sign of excitation can only be changed. For more advanced system where coded excitations can be used, more accurate implementation taking into account element sensitivity variations within each probe for closer adherence to the desired characteristics. The proposed system results in noise reduction that is equivalent to averaging N acquisitions similar to phase encoding in magnetic resonance imaging. At the same time, the system maintains the same lateral resolution and frame rate as conventional acquisition strategies. We also discuss the use of sub-optimal overlapped apertures and describe the deterioration of SNR gain as a result of using independent rather than orthogonal apertures.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Hany M. G. Hussein, Abou-Bakr M. Youssef, and Yasser M. Kadah "Encoded multiple simultaneous aperture acquisition for improved signal-to-noise ratio in ultrasound imaging", Proc. SPIE 5035, Medical Imaging 2003: Ultrasonic Imaging and Signal Processing, (23 May 2003); https://doi.org/10.1117/12.479900
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Ultrasonography

Signal to noise ratio

Chemical elements

Computer programming

Imaging arrays

Imaging systems

Magnetic resonance imaging

Back to Top