22 July 2003 GMR-based eddy current probes for RRA treated Al-7075 T6 and other high-temperature applications
Author Affiliations +
Abstract
Sensors for online monitoring of the heat treatment of aluminum alloys have been developed. The correlation between heat treatment parameters of Al 7075, the microstructure of the materials and NDE measurements has being studied systematically. By establishing correlations to the process parameters, it was assumed to be possible to devise a technique that provides not only insight into the aging process but also act as a quality control method for process verification. Multi-frequency eddy current allows compensation for environmental influences along with the ability to perform measurements at elevated temperatures and is therefore suitable for process monitoring.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ajay Siddoju, Ajay Siddoju, Samuel J. Kuhr, Samuel J. Kuhr, Norbert Meyendorf, Norbert Meyendorf, } "GMR-based eddy current probes for RRA treated Al-7075 T6 and other high-temperature applications", Proc. SPIE 5045, Testing, Reliability, and Application of Micro- and Nano-Material Systems, (22 July 2003); doi: 10.1117/12.483993; https://doi.org/10.1117/12.483993
PROCEEDINGS
7 PAGES


SHARE