The amorphous As40S15Se45 films as recording media for optical holography were studied. The results on research of transmission and Bragg grating holographic recording and readout conditions are presented. The recording of transmission holographic gratings was performed by He-Ne (0.6328 μm) or Kr+ (0.6764 μm) laser beam, while the readout of the diffraction efficiency was made at Bragg angle using He-Ne (0.6328 and 1.15 μm) or diode (0.805 μm) laser lines. It is shown that self-enhancement of Bragg grating reflectors is possible. The influence of thin film interference conditions on holographic recording parameters is demonstrated.
The alert did not successfully save. Please try again later.
Mara J. Reinfelde, Janis Teteris, Ilona Kuzmina, "Amorphous As-S-Se films for holographic recording," Proc. SPIE 5123, Advanced Optical Devices, Technologies, and Medical Applications, (8 August 2003);