6 October 2003 Stimulated rotational and vibrational Raman conversion of high-quality XeCl laser beam in hydrogen
Author Affiliations +
Proceedings Volume 5137, International Conference on Lasers, Applications, and Technologies 2002: Advanced Lasers and Systems; (2003) https://doi.org/10.1117/12.518075
Event: International Conference on Lasers, Applications, and Technologies 2002, 2002, Moscow, Russian Federation
Abstract
An experomental study of stimulated Raman conversion of high-coherent XeCl laser radiation in H2 has been carried out. About 50 vibrational-rotational components were realized with a circularly polarized laser beam pump. High spatial and temporal coherence of conversed radiation was obtained. Quantum efficiency of conversion in first vibrational Stokes was achieved 95%.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Nikolai G. Ivanov, Nikolai G. Ivanov, Valery F. Losev, Valery F. Losev, Vladimir Egorovich Prokop'ev, Vladimir Egorovich Prokop'ev, } "Stimulated rotational and vibrational Raman conversion of high-quality XeCl laser beam in hydrogen", Proc. SPIE 5137, International Conference on Lasers, Applications, and Technologies 2002: Advanced Lasers and Systems, (6 October 2003); doi: 10.1117/12.518075; https://doi.org/10.1117/12.518075