Translator Disclaimer
6 October 2003 Impact of temperature sensor location on the quality of control in laser welding
Author Affiliations +
Proceedings Volume 5229, Laser Technology VII: Applications of Lasers; (2003) https://doi.org/10.1117/12.520721
Event: Laser Technology VII: Applications of Lasers, 2002, Szczecin, Poland
Abstract
In the case of the laser welding control by means of the infrared thermographs, the information concerning the quality of the weld is obtained by using a temperature-measuring sensor at a specific point on the welding surface. In order to obtain good efficiency of the laser welding control, the point of the temperature measurement has to be chosen properly. In the present study, an attempt was made to determine an optimal position of the temperature sensor on the welding surface on the basis of comparative analysis of surface temperatures, which were obtained from experimental measurements and model calculations. It refers to laser welding of steel plate sheets.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
B. Grabas "Impact of temperature sensor location on the quality of control in laser welding", Proc. SPIE 5229, Laser Technology VII: Applications of Lasers, (6 October 2003); https://doi.org/10.1117/12.520721