Paper
23 December 2003 Dry actuation testing of viscous drag micropumping systems for determination of optimal drive waveforms
Brian D. Sosnowchik, Paul C. Galambos, Kendra V. Sharp, Mark W. Jenkins, Mark W. Horn, Jason R. Hendrix
Author Affiliations +
Abstract
This paper presents the dry actuation testing procedures and results for novel viscous drag micropumping systems. To overcome the limitations of previously developed mechanical pumps, we have developed pumps that are surface micromachined for efficient mass production which utilize viscous drag (dominant at low Reynolds numbers typical of microfluidics) to move fluid. The SUMMiT (www.sandia.gov/micromachine) fabricated pumps, presented first by Kilani et al., are being experimentally and computationally analyzed. In this paper we will describe the development of optimal waveforms to drive the electrostatic pumping mechanism while dry. While wet actuation will be significantly different, dry testing provides insight into how to optimally move the mechanism and differences between dry and wet actuation can be used to isolate fluid effects. Characterization began with an analysis of the driving voltage waveforms for the torsional ratcheting actuator (TRA), a micro-motor that drove the gear transmission for the pump, actuated with SAMA (Sandia’s Arbitrary waveform MEMS Actuator), a new waveform generating computer program with the ability to generate and output arbitrary voltage signals. Based upon previous research, a 50% duty cycle half-sine wave was initially selected for actuation of the TRA. However, due to the geometry of the half-sine waveform, the loaded micromotor could not transmit the motion required to pump the tested liquids. Six waveforms were then conceived, constructed, and selected for device actuation testing. Dry actuation tests included high voltage, low voltage, high frequency, and endurance/reliability testing of the TRA, gear transmission and pump assembly. In the SUMMiT process, all of the components of the system are fabricated together on one silicon chip already assembled in a monolithic microfabrication process. A 40% duty cycle quarter-sine waveform with a 20% DC at 60V has currently proved to be the most reliable, allowing for an 825Hz continuous TRA operating frequency for the micropumps. This novel waveform allowed for higher TRA actuation frequencies than those obtained in prior research of the pumps.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Brian D. Sosnowchik, Paul C. Galambos, Kendra V. Sharp, Mark W. Jenkins, Mark W. Horn, and Jason R. Hendrix "Dry actuation testing of viscous drag micropumping systems for determination of optimal drive waveforms", Proc. SPIE 5345, Microfluidics, BioMEMS, and Medical Microsystems II, (23 December 2003); https://doi.org/10.1117/12.527735
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Actuators

Microfluidics

Microelectromechanical systems

Teeth

Analytical research

Computer aided design

Wave propagation

RELATED CONTENT

Four segment piezo based micropump
Proceedings of SPIE (June 07 2017)
Design of MEMS and microsystems
Proceedings of SPIE (March 10 1999)
Important theory of array microjet based on MEMS
Proceedings of SPIE (September 10 2002)

Back to Top