6 May 2004 High-performance low-noise 128-channel readout-integrated circuit for flat-panel x-ray detector systems
Author Affiliations +
Abstract
A silicon mixed-signal integrated circuit is needed to extract and process x-ray induced signals from a coated flat panel thin film transistor array (TFT) in order to generate a digital x-ray image. Indigo Systems Corporation has designed, fabricated, and tested such a readout integrated circuit (ROIC), the ISC9717. This off-the-shelf, high performance, low-noise, 128-channel device is fully programmable with a multistage pipelined architecture and a 9 to 14-bit programmable A/D converter per channel, making it suitable for numerous X-ray medical imaging applications. These include high-resolution radiography in single frame mode and fluoroscopy where high frame rates are required. The ISC9717 can be used with various flat panel arrays and solid-state detectors materials: Selenium (Se), Cesium Iodide (CsI), Silicon (Si), Amorphous Silicon, Gallium Arsenide (GaAs), and Cadmium Zinc Telluride (CdZnTe). The 80-micron pitch ROIC is designed to interface (wire bonding or flip-chip) along one or two sides of the x-ray panel, where ROICs are abutted vertically, each reading out charge from pixels multiplexed onto 128 horizontal read lines. The paper will present the design and test results of the ROIC, including the mechanical and electrical interface to a TFT array, system performance requirements, output multiplexing of the digital signals to an off-board processor, and characterization test results from fabricated arrays.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Eric J. Beuville, Mark Belding, Adrienne N. Costello, Randy Hansen, and Susan M. Petronio "High-performance low-noise 128-channel readout-integrated circuit for flat-panel x-ray detector systems", Proc. SPIE 5368, Medical Imaging 2004: Physics of Medical Imaging, (6 May 2004); https://doi.org/10.1117/12.535842
PROCEEDINGS
12 PAGES


SHARE
Advertisement
Advertisement
RELATED CONTENT

FPGA based charge fast histogramming for GEM detector
Proceedings of SPIE (October 25 2013)
Energy response of ATHENA WFI prototype detectors
Proceedings of SPIE (July 06 2018)
Use Of A Charge Coupled Device In X Ray Astronomy...
Proceedings of SPIE (August 09 1979)
The CFHT CCD Detector
Proceedings of SPIE (November 08 1984)
Analysis of upper and lower bounds of the frame noise...
Proceedings of SPIE (November 01 1991)

Back to Top