8 October 2004 Analysis of the pseudocorrelation radiometers for the low frequency instrument onboard the PLANCK satellite
Author Affiliations +
Abstract
The Low Frequency Instrument aboard the PLANCK satellite will employ pseudo-correlation radiometers, operating over three broad bands centred at 30, 44 ,and 70 GHz. The radiometer scheme is based on the simultaneous comparison of two input signals, one coming from the sky and the other coming from a reference blackbody at a stable cryogenic temperature (near 4K) as close as possible to the sky temperature (about 2.7K). This choice is made in order to minimize non-white instrumental noise, typically exhibiting a 1/f spectrum. Effects due to the residual offset are minimised with a gain modulation factor applied in software. Fluctuations of the reference signal, due to fluctuation in the cooling chain or to straylight radiation, can also produce a parasitic signal which would mimic a true sky fluctuation. The PLANCK scientific goal of a high precision imaging of the CMB anisotropy requires an accurate characterisation of each part constituting the chain by using tools of modellisation and experimental tests. In this work we describe the concept of the radiometric chain, its functioning and the main sources of systematic errors, showing how, only with a hard modelling effort, it is possible to characterise, reduce and then remove in the data processing those systematic effects that may in principle compromise the quality of the whole instrument response.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Francesco Cuttaia, Francesco Cuttaia, Paola Battaglia, Paola Battaglia, Luca Terenzi, Luca Terenzi, Cristian Franceschet, Cristian Franceschet, Marco Bersanelli, Marco Bersanelli, Carlo Burigana, Carlo Burigana, Chris Reginald Butler, Chris Reginald Butler, O. D'Arcangelo, O. D'Arcangelo, Pietro Guzzi, Pietro Guzzi, Davide Maino, Davide Maino, Nazzareno Mandolesi, Nazzareno Mandolesi, Aniello Mennella, Aniello Mennella, Gianluca Morgante, Gianluca Morgante, Alessandro Simonetto, Alessandro Simonetto, Luca Valenziano, Luca Valenziano, Fabrizio Villa, Fabrizio Villa, } "Analysis of the pseudocorrelation radiometers for the low frequency instrument onboard the PLANCK satellite", Proc. SPIE 5498, Millimeter and Submillimeter Detectors for Astronomy II, (8 October 2004); doi: 10.1117/12.551857; https://doi.org/10.1117/12.551857
PROCEEDINGS
12 PAGES


SHARE
RELATED CONTENT

Heating of large format filters in sub mm and fir...
Proceedings of SPIE (November 16 2017)
Thermal models of the Planck/LFI QM/FM instruments
Proceedings of SPIE (June 27 2006)
Aerial thermography studies of power plant heated lakes
Proceedings of SPIE (March 29 2000)
Calibration and expected performances of ENVISAT-1 MWR
Proceedings of SPIE (December 16 1996)
The thermal analysis of polysiloxane rib waveguide
Proceedings of SPIE (November 15 2010)

Back to Top