Paper
4 November 2004 Spectral band difference effects on radiometric cross-calibration between multiple satellite sensors in the Landsat solar-reflective spectral domain
Author Affiliations +
Abstract
This paper reports on an investigation of radiometric calibration errors due to differences in spectral response functions between satellite sensors when attempting cross-calibration based on near-simultaneous imaging of common ground targets in analogous spectral bands. Five Earth observation sensors on three satellite platforms were included on the basis of their overpass times being within 45 minutes of each other on the same day (Landsat-7 ETM+; EO-1 ALI; Terra MODIS; Terra ASTER; Terra MISR). The simulation study encompassed spectral band difference effects (SBDE) on cross-calibration between all combinations of the sensors considered, using the Landsat solar reflective spectral domain as a framework. Scene content was simulated using ground target spectra for the calibration test sites at Railroad Valley Playa, Nevada and Niobrara Grassland, Nebraska. Results were obtained as a function of calibration test site, satellite sensor, and spectral region. Overall, in the absence of corrections for SBDE, the Railroad Valley Playa site is a "good" to "very good" ground target for cross-calibration between most but not all satellite sensors considered in most but not all spectral regions investigated. "Good" and "very good" are defined as SBDEs within +/- 3 % and +/- 1 %, respectively. Without SBDE corrections, the Niobrara test site is only "good" for cross-calibration between certain sensor combinations in some spectral regions. The paper includes recommendations for spectral data and tools that would facilitate cross-calibration between multiple satellite sensors.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Philippe M. Teillet, Gunar Fedosejevs, and Kurtis J. Thome "Spectral band difference effects on radiometric cross-calibration between multiple satellite sensors in the Landsat solar-reflective spectral domain", Proc. SPIE 5570, Sensors, Systems, and Next-Generation Satellites VIII, (4 November 2004); https://doi.org/10.1117/12.562709
Lens.org Logo
CITATIONS
Cited by 7 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Satellites

Earth observing sensors

Landsat

MODIS

Calibration

Reflectivity

RELATED CONTENT

Vicarious calibration of KOMPSAT-3 AEISS
Proceedings of SPIE (October 12 2015)
SBAF for cross calibration of Landsat 8 OLI and Sentinel...
Proceedings of SPIE (September 07 2018)
Ground-monitor radiometer system for vicarious calibration
Proceedings of SPIE (October 15 2004)
Cross calibration of MODIS with ETM+ and ALI sensors for...
Proceedings of SPIE (September 08 2006)
Cross calibration of the Terra MODIS, Landsat 7 ETM+ and...
Proceedings of SPIE (October 05 2007)

Back to Top