19 November 2004 Research on the gray distortion and calibration of machine vision system
Author Affiliations +
Abstract
The laws of gray distortion of machine vision system were discussed, and a method for gray calibration was presented. Five standard templates with unanimous gray value were used as the research objects. The average gray values of X direction and Y direction of the standard template images were obtained according to row and column. The gray distortion models were developed with moving average model of two image pixels. The models of five standard templates were developed separately, and the correlation coefficients of each model were above 0.96. The parameters of the gray distortion model were independent to the templates themselves. The gray calibration models of row and column were developed based on the gray distortion models separately, and the image gray values of other templates were proportion to the true value after gray calibration with the gray calibration models. The test verified the method.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yucheng Ye, Jianping Wang, Yibin Ying, Xiuqin Rao, "Research on the gray distortion and calibration of machine vision system", Proc. SPIE 5587, Nondestructive Sensing for Food Safety, Quality, and Natural Resources, (19 November 2004); doi: 10.1117/12.571274; https://doi.org/10.1117/12.571274