Paper
21 February 2005 Excimer laser conditioning of KDP: correlation of nondestructive optical diagnostics at 351nm with laser damage threshold
Author Affiliations +
Abstract
We investigated the crystals with different non-destructive optical diagnostics during the conditioning of KDP with an excimer laser at 351 nm. We measured in the same time the luminescence, the absorption and bulk scattering of the material. These observations pointed out the defects within the crystal. We demonstrated a correlation of the optical signal intensity with the laser damage threshold of KDP.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
David Damiani, Herve Piombini, and Daniel Plessis "Excimer laser conditioning of KDP: correlation of nondestructive optical diagnostics at 351nm with laser damage threshold", Proc. SPIE 5647, Laser-Induced Damage in Optical Materials: 2004, (21 February 2005); https://doi.org/10.1117/12.584706