The IR Upgrade FEL at the Thomas Jefferson National Accelerator Facility (JLab) was used to make measurements of the absorption in laser cavity mirrors, both high reflectors and outcouplers. Measurements were made at 10, 6, and 3 um, by determining the temperature rise of the cooling water of the FEL cavity mirrors while operating at high average power, and by using a laser vacuum calorimeter and interpreting the data using the ISO 11551 standard.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Michelle D. Shinn, Christopher Behre, Stephen V. Benson, David Hardy, Joseph Gubeli III, George R. Neil, and Shukui Zhang "Measurement of absorption levels in mid-infrared coated optics", Proc. SPIE 5647, Laser-Induced Damage in Optical Materials: 2004, (21 February 2005); https://doi.org/10.1117/12.585364