Paper
14 January 1986 Photogrammetric Techniques Using High-Speed Cineradiography
Guy S. Nusholtz, Max Bender, Bryan R. Suggitt, Patricia S. Kaiker, Gail J. Muscott
Author Affiliations +
Abstract
A high-speed 16-mm cineradiographic system previously developed at the University of Michigan Transportation Research Institute for use in biomechanics research has been undergoing a continuous upgrading in capability. In addition to changes in the structural aspect of the cineradiography, improvements have been made in the procedures used to obtain better image quality as well as methods for interpretation of the digitized results. The current improvements in the system include: 1) filtering the X-ray source before penetration of the subject to increase image contrast as well as to protect the image tube; 2) pre-processing of the film to increase its effective speed; 3) development of a neutral density radio-contrast media for outlining anatomical structure without using the vascular system; and 4) development of procedures for obtaining analytical information about motion of non-rigid anatomical structures from digitized film. This system now consists of either a 35-mm Photosonics 4B, a 16-mm Photosonics 1B, or a 16-mm Milliken which views a 50-mm (2-inch) diameter output of a P-11 phosphor of a high gain, four-stage magnetically focused image intensifier tube, gated on and off synchronously with the motion picture camera shutter. A lens optically couples the input photocathode of the image tube to an X-ray fluorescent (rare earth) screen image produced by a smoothed DC X-ray generator of a conventional type. The system is capable of looking at a large spectrum of anatomical structures under a wide range of dynamic loading conditions.
© (1986) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Guy S. Nusholtz, Max Bender, Bryan R. Suggitt, Patricia S. Kaiker, and Gail J. Muscott "Photogrammetric Techniques Using High-Speed Cineradiography", Proc. SPIE 0569, High Speed Photography, Videography, and Photonics III, (14 January 1986); https://doi.org/10.1117/12.949857
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Image intensifiers

Electrons

Brain

Spine

X-ray imaging

Absorption

RELATED CONTENT

Digital Method To Evaluate The Noise Of X Ray Image...
Proceedings of SPIE (December 26 1979)
Flash X-Ray Cineradiography At 100,000 Fps
Proceedings of SPIE (March 01 1983)
New progress in high-performance x-ray image intensifiers
Proceedings of SPIE (April 01 1993)
Recent developments in x-ray ICCD cameras
Proceedings of SPIE (November 11 1994)
Multianode cine flash x-ray system
Proceedings of SPIE (January 01 1993)
New Cine X-Ray Systems
Proceedings of SPIE (February 01 1985)

Back to Top