Paper
12 April 2005 Registration of high-resolution 3D atrial images with electroanatomical cardiac mapping: evaluation of registration methodology
Yiyong Sun, Fred S. Azar, Chenyang Xu, Gal Hayam, Assaf Preiss, Norbert Rahn, Frank Sauer
Author Affiliations +
Abstract
Registration of atrial high-resolution CT and MR images with a cardiac mapping system can provide real-time electrical activation information, catheter tracking, and recording of lesion position. The cardiac mapping and navigation system comprises a miniature passive magnetic field sensor, an external ultralow magnetic field emitter (location pad), and a processing unit (CARTO, BiosenseWebster). We developed a progressive methodology for both interactively and automatically registering high-resolution 3D atrial images (MR or CT) with the corresponding electrophysiological (EP) points of 3D electro-anatomical (EA) maps. This methodology consists of four types of registration algorithms ranging from landmark-based to surface-based registration. We evaluated the methodology through phantom and patient studies. In the phantom study, we obtain a CT scan of a transparent heart phantom, and then use the CARTO system to visually pick a number of points inside the transparent phantom. After segmenting the atrium into a 3D surface, we register it to the measured EA map. The results are compared to the manual EA point measurements. In the 13-patient study, the four types of registrations are evaluated: visual alignment, landmark registration (three EA points are used), surface-based registration (all EA points are used), and local surface-based registration (a subset of the EA points is used, and one specific point is given a higher weight for a better “local registration”). Surface-based registration proves to be clearly superior to visual alignment. This new registration methodology may help in creating a novel and more visually interactive workflow for EP procedures, with more accurate EA map acquisitions. This may improve the ablation accuracy in atrial fibrillation (AFib) procedures, decrease the dependency on fluoroscopy, and also lead to less radiation delivered to the patient.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yiyong Sun, Fred S. Azar, Chenyang Xu, Gal Hayam, Assaf Preiss, Norbert Rahn, and Frank Sauer "Registration of high-resolution 3D atrial images with electroanatomical cardiac mapping: evaluation of registration methodology", Proc. SPIE 5744, Medical Imaging 2005: Visualization, Image-Guided Procedures, and Display, (12 April 2005); https://doi.org/10.1117/12.595459
Lens.org Logo
CITATIONS
Cited by 11 scholarly publications and 4 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Visualization

Image registration

Computed tomography

3D image processing

Heart

Associative arrays

Magnetic resonance imaging

Back to Top