Onera has designed and developed an scientific airborne infrared measurement system. This system is constituted of a supervisor computer and two scientific instruments (a cryogenic IR multiband camera and a cryogenic IR spectro-radiometer). This article presents the different elements of the system and focuses on the design of the cryogenic IR camera. The IR camera design involves instrument control, data acquisition, IRIG time stamping, target acquisition and tracking. This article highlights also the communication design using two Ethernet networks linking the elements of the experimental measurement chain.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Laurent Rousset-Rouviere, Laurent Rousset-Rouviere, Christophe Marchon, Christophe Marchon, Sebastien Vendomele, Sebastien Vendomele, Christophe Coudrain, Christophe Coudrain, Jean-Paul Bruyant, Jean-Paul Bruyant, } "System design of an airborne infrared measurement system", Proc. SPIE 5787, Airborne Intelligence, Surveillance, Reconnaissance (ISR) Systems and Applications II, (10 May 2005); doi: 10.1117/12.604303; https://doi.org/10.1117/12.604303