29 June 2005 Implementation on DSP of an active contour algorithm for endocardium tracking in echocardiographic images
Author Affiliations +
Abstract
In first place, in this paper, the basic process of parallel code implementation is discussed for a VLIW architecture. Parallel code modules allow the implementation of a contour active (snake) for segmentation and tracking of endocardium in echocardiographic images. In second place, this work discusses the performance obtained through this design model. In this case, it is necessary to check performances in order to obtain a qualitative and quantitative measurement of our implementation. We have chosen one example which permits to understand the methodology used in order to obtain the maximum performance of hardware features of VLIW processor: the distance between points of active contour, very used in different modules composing the active contour algorithm.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Juan F. Zapata, Juan F. Zapata, Ramon J. Ruiz, Ramon J. Ruiz, } "Implementation on DSP of an active contour algorithm for endocardium tracking in echocardiographic images", Proc. SPIE 5839, Bioengineered and Bioinspired Systems II, (29 June 2005); doi: 10.1117/12.608267; https://doi.org/10.1117/12.608267
PROCEEDINGS
11 PAGES


SHARE
RELATED CONTENT

Image Matching Algorithms
Proceedings of SPIE (July 21 1985)
Using Contextual Information In Classification Algorithms
Proceedings of SPIE (April 05 1987)
Rule-Based Orientation Recognition Of A Moving Object
Proceedings of SPIE (March 20 1989)
Expandable Image Compression System, A Modular Approach
Proceedings of SPIE (December 31 1986)

Back to Top