25 August 2005 Total ionizing dose and proton radiation characterization of Si P-i-N visible hybrid focal plane arrays
Author Affiliations +
Proceedings Volume 5902, Focal Plane Arrays for Space Telescopes II; 59020M (2005); doi: 10.1117/12.625538
Event: Optics and Photonics 2005, 2005, San Diego, California, United States
Abstract
The results of total ionizing dose and proton fluence characterization of hybrid Si P-i-N focal plane arrays are reported. The focal plane arrays consist of a silicon P-i-N detector array bump bonded to 128 x 128 CMOS readout integrated circuit (ROIC). The FPAs were characterized in total ionizing dose and proton fluence radiation environments. Full radiometric characterizations were performed at each radiation dose level to determine the impact of the radiation on dark current, noise, responsivity, sensitivity, and dynamic range. Results from the total ionizing dose experiment demonstrate an unexpected increase in the visible P-i-N detector dark current. The median dark current increased more than two orders of magnitude from pre-radiation to 300 krad(Si) and the magnitude of the dark current was found to be a strong function of detector bias. No appreciable change in responsivity or noise was observed for wavelengths above 400 nm up to a total ionizing dose of 750 krad(Si). Results from the proton radiation experiment show no appreciable change in responsivity was observed up to a 63 MeV proton fluence of 3 x 1012 protons/cm2 (400 krad(Si) of total ionizing dose). The median dark current increased approximately two orders of magnitude, but even at this higher level, the dark current did not contribute significantly to the median noise at an integration time of 10 ms. The dominant degradation mechanism, in both the total ionizing dose and proton fluence environments, is an increase in dark current in the Si P-i-N detectors.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
John E. Hubbs, Mark E. Gramer, Douglas C. Arrington, Gary A. Dole, Diana Maestas-Jepson, Sheldon E. Takeall, "Total ionizing dose and proton radiation characterization of Si P-i-N visible hybrid focal plane arrays", Proc. SPIE 5902, Focal Plane Arrays for Space Telescopes II, 59020M (25 August 2005); doi: 10.1117/12.625538; https://doi.org/10.1117/12.625538
PROCEEDINGS
15 PAGES


SHARE
KEYWORDS
Staring arrays

Sensors

Silicon

Readout integrated circuits

Visible radiation

Quantum efficiency

Detector arrays

RELATED CONTENT

Space mid-IR detectors from DRS
Proceedings of SPIE (March 05 2003)
FPA technology advancements at Rockwell Scientific
Proceedings of SPIE (May 31 2005)
State-of-the-art HgCdTe infrared devices
Proceedings of SPIE (April 13 2000)
1024 x 1024 Si As IBC detector arrays for JWST...
Proceedings of SPIE (August 25 2005)

Back to Top