7 October 2005 Measurement of optical transmittance applied to determination of bio-component contents in diesel oil
Author Affiliations +
Abstract
The results of spectroscopic and chromatographic investigations of fuel containing the different content of bio-compounds were presented and analysed. The transmittance values at 1744 cm-1 wave number were used as a measure of total rapeseed oil methyl esters' (RME) concentrations. The microprocessor device for RME content determination was described. The presented dependence of transmittance around 1744 cm-1 on RME concentration can be applied to the determination of RME content in fuel.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jacek Golebiowski, "Measurement of optical transmittance applied to determination of bio-component contents in diesel oil", Proc. SPIE 5948, Photonics Applications in Industry and Research IV, 59482L (7 October 2005); doi: 10.1117/12.623342; https://doi.org/10.1117/12.623342
PROCEEDINGS
8 PAGES


SHARE