20 February 2006 Digital holographic optical coherence imaging of tumor tissue
Author Affiliations +
Proceedings Volume 6079, Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine X; 60791G (2006); doi: 10.1117/12.646686
Event: SPIE BiOS, 2006, San Jose, California, United States
Abstract
Holographic Optical Coherence Imaging (OCI) uses spatial heterodyne detection in direct analogy with the temporal heterodyne detection of time-domain OCT. The spatial demodulator can be a sensitive dynamic holographic film or can be a CCD array placed directly at the hologram plane. We show that a digital hologram captured at the Fourier plane requires only a simple 2D inverse FFT of the digital hologram to compute the real image and its conjugate. Our recording on the optical Fourier plane has an advantage for diffuse targets because the intensity distribution of diffuse targets is relatively uniform at the Fourier plane and hence uses the full dynamic range of CCD camera. We applied this technique to human liver tumor spheroids and produced depth-resolved images to depth of 1.4 mm.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Kwan Jeong, John J. Turek, David D. Nolte, "Digital holographic optical coherence imaging of tumor tissue", Proc. SPIE 6079, Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine X, 60791G (20 February 2006); doi: 10.1117/12.646686; https://doi.org/10.1117/12.646686
PROCEEDINGS
10 PAGES


SHARE
KEYWORDS
Digital holography

Holograms

Holography

Tumors

CCD cameras

Liver

Coherence imaging

Back to Top