You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
15 February 2006High-OH fibers with higher stability in the UV-region
For medical and analytical applications, step-index fibers based on synthetic silica are widely used. For special applications, high-OH all-silica fibers with excellent UV-transmission are commercially available, even at 180 nm. E'-centers with an absorption band around 215 nm, generated by the UV-light transported in these fibers, have to be taken into account. In addition to stable E'-centers, transient defects exist at room temperature, as well; therefore, the transmission at 215 nm wavelength depends on the operational conditions.
The newly developed fibers with different diameters (from 100 μm to 600 μm core) will have a reduced defect concentration at 215 nm. In addition, the transient defect concentration has been reduced, too. The variation between the two power levels (dark, light) depends on the fiber diameter: the value is less than 0.3 dB/2m or 30 mAU/2m for large core fibers, one magnitude of order better than the comparable UVM-fiber described above. The hydrogen-content of the new fibers is negligible; therefore, the long-term behavior of these fibers, from 100 μm to 600 μm core diameter, is significantly better. In addition to low-power deuterium-lamps, the UV-damage of these fibers has been studied with high-power pulsed UV-lasers at 193 nm wavelength. Using the standard high-OH UV-fibers and UVM-fibers for comparison, the damage results will be discussed in detail. In addition, the established system for quality control of these UV-fibers will be described.
The alert did not successfully save. Please try again later.
Valery Kh. Khalilov, Karl-Friedrich Klein, Jalal Belmahdi, Rick Timmerman, Gary Nelson, "High-OH fibers with higher stability in the UV-region," Proc. SPIE 6083, Optical Fibers and Sensors for Medical Diagnostics and Treatment Applications VI, 608308 (15 February 2006); https://doi.org/10.1117/12.651639