7 March 2006 Wavefront corrector requirements for compensation of ocular aberrations in two large populations of normal human eyes
Author Affiliations +
Proceedings Volume 6138, Ophthalmic Technologies XVI; 61380X (2006) https://doi.org/10.1117/12.648122
Event: SPIE BiOS, 2006, San Jose, California, United States
Abstract
Numerous types of wavefront correctors have been employed in adaptive optics (AO) systems for correcting the wave aberrations of the eye. While each has been shown to reduce the degrading impact of the ocular aberrations, none have shown sufficient correction to yield diffraction-limited imaging for large pupils (≥6 mm), where the aberrations are most severe and the benefit of AO is largest. As the wavefront corrector appears to be the limiting AO component, it raises a fundamental concern as to what characteristics of this device, in particular actuator stroke and number, are required to achieve diffraction-limited imaging, and to optimally match corrector performance and cost to that required of a particular imaging task in the eye. In this paper, we model the performance of discrete actuator deformable mirrors, piston-only segmented mirrors, and piston/tip/tilt segmented mirrors in conjunction with wavefront aberrations measured on human eyes in two large population datasets (University of Rochester and Indiana University). The actuator stroke and number required to achieve diffraction-limited imaging for a 7.5 mm pupil were found to be highly dependent on the level of 2nd order aberrations and the population considered. Specifically, the required stroke for encompassing 95% of the population ranged from 12-53 (Rochester) and 7-11 (Indiana) microns. The wide range resulted from whether 2nd order aberrations were corrected or set to zero prior to correction. To achieve a Strehl > 0.8, the actuator number across the pupil diameter ranged from >14 (Rochester) and 11-14 (Indiana) for discrete actuator deformable mirrors, >95 (Rochester) and 50-90 (Indiana) for piston-only segmented mirrors, and finally 12-19 (Rochester) and 9-10 (Indiana) for piston/tip/tilt segmented mirrors.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Nathan Doble, Donald T. Miller, Geunyoung Yoon, Michael A. Helmbrecht, David R. Williams, "Wavefront corrector requirements for compensation of ocular aberrations in two large populations of normal human eyes", Proc. SPIE 6138, Ophthalmic Technologies XVI, 61380X (7 March 2006); doi: 10.1117/12.648122; https://doi.org/10.1117/12.648122
PROCEEDINGS
10 PAGES


SHARE
RELATED CONTENT

Novel unimorph deformable mirror for ocular adaptive optics
Proceedings of SPIE (November 18 2014)
Low-order AO system in LAMOST
Proceedings of SPIE (June 28 2006)
Segmented Mirrors For Atmospheric Compensation
Proceedings of SPIE (September 26 1989)
GREGOR AO as a tool for telescope commissioning
Proceedings of SPIE (June 23 2006)
Requirements for MEMS mirrors for adaptive optics in the eye
Proceedings of SPIE (January 23 2006)

Back to Top