13 March 2006 Evaluation of an asymmetric stent patch design for a patient specific intracranial aneurysm using computational fluid dynamic (CFD) calculations in the computed tomography (CT) derived lumen
Minsuok Kim, Ciprian Ionita, Rekha Tranquebar, Kenneth R. Hoffmann, Dale B. Taulbee, Hui Meng, Stephen Rudin
Author Affiliations +
Abstract
Stenting may provide a new, less invasive therapeutic option for cerebral aneurysms. However, a conventional porous stent may be insufficient in modifying the blood flow for clinical aneurysms. We designed an asymmetric stent consisting of a low porosity patch welded onto a porous stent for an anterior cerebral artery aneurysm of a specific patient geometry to block the strong inflow jet. To evaluate the effect of the patch on aneurysmal flow dynamics, we "virtually" implanted it into the patient's aneurysm geometry and performed Computational Fluid Dynamics (CFD) analysis. The patch was computationally deformed to fit into the vessel lumen segmented from the patient CT reconstructions. After the flow calculations, a patch with the same design was fabricated using laser cutting techniques and welded onto a commercial porous stent, creating a patient-specific asymmetric stent. This stent was implanted into a phantom, which was imaged with X-ray angiography. The hemodynamics of untreated and stented aneurysms were compared both computationally and experimentally. It was found from CFD of the patient aneurysm that the asymmetric stent effectively blocked the strong inflow jet into the aneurysm and eliminated the flow impingement on the aneurysm wall at the dome. The impact zone with elevated wall shear stress was eliminated, the aneurysmal flow activity was substantially reduced, and the flow was considerably reduced. Experimental observations corresponded well qualitatively with the CFD results. The demonstrated asymmetric stent could lead to a new minimally invasive image guided intervention to reduce aneurysm growth and rupture.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Minsuok Kim, Ciprian Ionita, Rekha Tranquebar, Kenneth R. Hoffmann, Dale B. Taulbee, Hui Meng, and Stephen Rudin "Evaluation of an asymmetric stent patch design for a patient specific intracranial aneurysm using computational fluid dynamic (CFD) calculations in the computed tomography (CT) derived lumen", Proc. SPIE 6143, Medical Imaging 2006: Physiology, Function, and Structure from Medical Images, 61432G (13 March 2006); https://doi.org/10.1117/12.651773
Lens.org Logo
CITATIONS
Cited by 12 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Angiography

Arteries

Hemodynamics

Neck

Blood circulation

Computational fluid dynamics

Visualization

Back to Top