Paper
16 March 2006 Acoustic thermography using an uncooled high-speed camera and low-power ultrasonic excitation: test system and its application to impact flaw detection in CFRP
Author Affiliations +
Abstract
Acoustic thermography is a relatively new NDE method based on thermographic detection of dissipated ultrasonic energy. The system presented uses an uncooled high-speed camera and low power ultrasonic excitation. This technology is characterized by low system costs, since no nitrogen or stirling cooling is necessary. Low power applications are facilitated by efficient ultrasonic coupling, hence taking care of sensitive objects. A camera has been developed which uses a 384 x 288 pixels micro-bolometer array as sensor and may record up to 100 frames per second. The advantages of this system are demonstrated on a set of carbon fiber reinforced plastic (CFRP) plates damaged by impacts of various strengths. The impact flaws consisting of fiber fractures and delaminations can be detected while transmitting low ultrasonic energy of only about 1.3 W to the specimen.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Lothar Haupt, Manfred Zimmerhackl, Norbert Meyendorf, and Bernd Köhler "Acoustic thermography using an uncooled high-speed camera and low-power ultrasonic excitation: test system and its application to impact flaw detection in CFRP", Proc. SPIE 6179, Advanced Sensor Technologies for Nondestructive Evaluation and Structural Health Monitoring II, 617903 (16 March 2006); https://doi.org/10.1117/12.660766
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Ultrasonics

Thermography

Actuators

Cameras

Acoustics

Imaging systems

High speed cameras

Back to Top