22 April 2006 Red blood cell optical parameters in single and multiple light scattering models
Author Affiliations +
Proceedings Volume 6189, Optical Sensing II; 61891O (2006); doi: 10.1117/12.662215
Event: SPIE Photonics Europe, 2006, Strasbourg, France
Abstract
Results of single and multiple light scattering simulations for erythrocytes (RBC) modelled as spheroids are presented. The normal conditions as well as changes of osmotic pressure, hematocrit level and haemoglobin saturation were analysed. The computations were carried out with the use of the T-Matrix and Monte Carlo methods. The obtained results were compared with simulations based on spherical and cylindrical models. There were no significant qualitative differences between the cylindrical and spheroid models in case of multiple scattering. Somewhat larger differences between the spherical and the two other models were observed.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Janusz Mroczka, Dariusz Wysoczański, "Red blood cell optical parameters in single and multiple light scattering models", Proc. SPIE 6189, Optical Sensing II, 61891O (22 April 2006); doi: 10.1117/12.662215; https://doi.org/10.1117/12.662215