1 November 2007 Thermal and electrical performance of α-Si microbolometer focal plane arrays
Author Affiliations +
Proceedings Volume 6423, International Conference on Smart Materials and Nanotechnology in Engineering; 64232D (2007) https://doi.org/10.1117/12.779855
Event: International Conference on Smart Materials and Nanotechnology in Engineering, 2007, Harbin, China
Abstract
Recent advances of microelectromechanical system (MEMS) technology have opened new opportunities for amorphous silicon (α-Si) microbolometer focal plane arrays (FPAs) both for military and civil applications. α-Si membrane is chosen for sensitive material of microbolometer FPAs due to its high temperature coefficient of resistance (TCR), high resistivity and good mechanical properties. However, α-Si membrane also has the disadvantage of high 1/f noise, strict preparation conditions and metastable effect. So nowadays, researches are focused on properties of α-Si membrane to gain high performance of microbolometer FPAs. Since the pulsed bias readout mode of microbolometer FPAs causes a non-steady-state of α-Si membrane during the operation, the transient thermal-electrical response process of the sensing pixel is analyzed detailedly in this paper to predict the thermal and electrical performance of α-Si microbolemeter FPAs such as responsivity, noise equivalent temperature difference (NETD), detectivity and power dissipation. Numerical simulations are presented to investigate the factor which affects the performance of α-Si microbolometer FPAs. The imaging experiment results obtained from a 320×240 α-Si microbolemeter FPA are in good agreement with the theoretical analysis. The way to improve the performance of α-Si microbolemeter FPAs is given in the end of this paper.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Lianjun Sun, Benkang Chang, Junju Zhang, Yunsheng Qian, and Yafeng Qiu "Thermal and electrical performance of α-Si microbolometer focal plane arrays", Proc. SPIE 6423, International Conference on Smart Materials and Nanotechnology in Engineering, 64232D (1 November 2007); https://doi.org/10.1117/12.779855
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Staring arrays

Microbolometers

Lead

Amorphous silicon

Microelectromechanical systems

Numerical simulations

Resistance

Back to Top